ANSI C63.4-2003 (1 - 18 GHz) Scheme
Share |


 

Required Measurements

In the ANSI C63.4-2003 (1 - 18 GHz) Scheme, participants are required to make the following kinds of measurements:
  • Direct Antenna Conducted Emissions Peak measurements.
  • Direct Antenna Conducted Emissions Average measurements.
  • Radiated Emissions Peak measurements at the 3 m distance, in Horizontal Polarization.
  • Radiated Emissions Average measurements at the 3 m distance, in Horizontal Polarization.
  • Radiated Emissions Peak measurements at the 3 m distance, in Vertical Polarization.
  • Radiated Emissions Average measurements at the 3 m distance, in Vertical Polarization. 

Major Equipment and Facilities Pre-requisite Requirements

Major Requirements:
The OATS or RF Semi-Anechoic Chamber Facilities used must meet ONLY the Site Validation criteria of ANSI C63.4-2003.  A Calibrated EMI Receiver or Calibrated Spectrum Analyzer  is required.  A Wood Table is required. Horn and/or Hybrid Antennas that have been calibrated either per ANSI C63.5-1988 or per ANSI C63.5-1998) are required. Note: if your antennas were calibrated per ANSI C63.5-2006, please enroll in the ANSI C63.4-2009 (1 GHz- 18 GHz) Scheme rather than this Scheme.
 
Prohibited Items:
Time-Domain Receivers are prohibited. The use of EPS (e.g., Styrofoam®) tables, foam columns, and cell-phone support towers are prohibited. 

Cost

First participant (test operator) at a given location
$1,600
Additional participants (2nd through 4th participant at same location)
$300 each
One additional week at same location (up to 4 additional participants)
$1,200